Neris, J.; Doerr, S.H.; Santin, C.; Sanchez-Garcia, C.; Robichaud, P.R.
Ash transport by surface runoff using a laboratory flume–based experiment
This dataset is under embargo and will be made available by 10 April 2025 at the latest Find out more »
Cite this dataset as:
Neris, J.; Doerr, S.H.; Santin, C.; Sanchez-Garcia, C.; Robichaud, P.R. (2023). Ash transport by surface runoff using a laboratory flume–based experiment. NERC EDS Environmental Information Data Centre. https://doi.org/10.5285/351e2785-5a1e-4dbb-97c1-052f1290f0be
Download/Access
This dataset is under embargo and will be made available by 10 April 2025 at the latest Find out more »
https://doi.org/10.5285/351e2785-5a1e-4dbb-97c1-052f1290f0be
This dataset describes measurements of transport of ash by surface runoff using a laboratory setup (flumes). In the experiment, three inflow rates (0.25, 1 and 2 L/min) were applied to two typical ash depths found after wildfires (1 and 3 cm).
Variables measured include ash depth (cm), inflow rate (L/min), runoff rate (L/sec), ash transport rate (g/sec), ash concentration in the runoff (g/L).
Variables measured include ash depth (cm), inflow rate (L/min), runoff rate (L/sec), ash transport rate (g/sec), ash concentration in the runoff (g/L).
Publication date: 2023-10-12
517 views *
View numbers valid from 12 October 2023 (information prior to this was not collected)
Format
Comma-separated values (CSV)
Provenance & quality
Six flumes were filled with ash (1 and 3 cm depth) and three inflow rates (L = 0.25 L/min, M = 1 L/min and H = 2 L/min) applied consecutively to each flume for 10 min in a different order to cover the six possible combinations (L-M-H, L-H-M, M-L-H, M-H-L, H-L-M, H-M-L). Six replicates per ash depth and inflow rate combination were conducted.
Six runoff samples containing transported ash were taken at the flumes’ outlet at specific times (0, 1.5, 3, 6, 7.5 and 9). Samples were taken in plastic bottles for 15 seconds. Samples were weighed, dried (105 oC for 48 h) and weighed again to calculate runoff volume and ash weight. Inflow rate (L/min), runoff rate (L/sec), ash transport rate (g/sec), ash concentration (g/L) were calculated using the data obtained for the samples (volume, weight and time).
Six runoff samples containing transported ash were taken at the flumes’ outlet at specific times (0, 1.5, 3, 6, 7.5 and 9). Samples were taken in plastic bottles for 15 seconds. Samples were weighed, dried (105 oC for 48 h) and weighed again to calculate runoff volume and ash weight. Inflow rate (L/min), runoff rate (L/sec), ash transport rate (g/sec), ash concentration (g/L) were calculated using the data obtained for the samples (volume, weight and time).
Licensing and constraints
This dataset is under embargo and will be made available by 10 April 2025 at the latest Find out more »
This dataset will be available under the terms of the Open Government Licence
Cite this dataset as:
Neris, J.; Doerr, S.H.; Santin, C.; Sanchez-Garcia, C.; Robichaud, P.R. (2023). Ash transport by surface runoff using a laboratory flume–based experiment. NERC EDS Environmental Information Data Centre. https://doi.org/10.5285/351e2785-5a1e-4dbb-97c1-052f1290f0be