Slavin, E.I.; Wain, D.J.
Water temperature measurements from Durleigh Reservoir 2018
Cite this dataset as:
Slavin, E.I.; Wain, D.J. (2020). Water temperature measurements from Durleigh Reservoir 2018. NERC Environmental Information Data Centre. https://doi.org/10.5285/25d34c83-e939-40fd-aa16-6962efb4c731
Download/Access
PLEASE NOTE:
By accessing or using this dataset, you agree to the terms of the relevant licence agreement(s). You will ensure that this dataset is cited in any publication that describes research in which the data have been used.
© University of Bath
This dataset is available under the terms of the Open Government Licence
https://doi.org/10.5285/25d34c83-e939-40fd-aa16-6962efb4c731
This dataset contains water temperature measurements at two different locations in Durleigh Reservoir in Somerset, England. Water temperatures were measured using RBR SoloT thermistors (measured in deg C) and HOBO TidbiT v2 loggers (measured in deg F). The dataset consists of water temperature measurements from two locations at Durleigh reservoir between 22 February 2018 and 5 October 2018. Measurements were taken at 10 minute intervals.
Publication date: 2020-05-05
View numbers valid from 01 June 2023 Download numbers valid from 20 June 2024 (information prior to this was not collected)
Format
Comma-separated values (CSV)
Spatial information
Study area
Spatial representation type
Tabular (text)
Spatial reference system
OSGB 1936 / British National Grid
Temporal information
Temporal extent
2018-02-22 to 2018-10-05
Provenance & quality
The first site, labelled location 2, is closer to the artificial mixing devices (surface mixers) installed in the reservoir (60 m away) and deeper, with a water depth of 6 m when on deployment (latitude: 51.1210, longitude: -3.0403). The second site, labelled location 3, is farther away from the artificial mixing devices installed in the reservoir (435 m away) and in a shallower region, with a water depth of 4 m on deployment (latitude: 51.1215, longitude: -3.0445). At location 2, RBR SoloT thermistors (measured in deg C) were positioned at 1 m intervals from the surface (0 m depth) to the bottom of the water column (6 m). However, in the dataset temperature measurements from thermistors positioned at 1 m, 2 m, and 3 m are missing due to corrupted files. At location 3, HOBO TidbiT v2 loggers (measured in deg F) were positioned at 1 m intervals from the surface (0 m depth) to the bottom of the water column (4 m depth). All water temperature measurements were taken at 10-minute intervals. Both temperature chains consisted of a buoy (A2 size) attached to a 10 kg weight using a rope, and the thermistors were attached onto the rope. All thermistors were deployed between 22 February and 5 October 2018.
Licensing and constraints
This dataset is available under the terms of the Open Government Licence
Cite this dataset as:
Slavin, E.I.; Wain, D.J. (2020). Water temperature measurements from Durleigh Reservoir 2018. NERC Environmental Information Data Centre. https://doi.org/10.5285/25d34c83-e939-40fd-aa16-6962efb4c731
© University of Bath
Correspondence/contact details
Authors
Other contacts
Custodian
NERC EDS Environmental Information Data Centre
info@eidc.ac.uk
Publisher
NERC Environmental Information Data Centre
info@eidc.ac.uk